, , ,

MVP-50T NON CERTIFIED TURBOPROP & JET ENGINE MONITOR

Part #: MVP-50T-PT6, MVP-50T-W, MVP-50T-G, MVP-50T-L, MVP-50T-A, MVP-50T-J85, MVP-50T-L39
Electronics International
Availability:

Out of stock


MVP50TPT6, MVP50TW, MVP50TG, MVP50TL, MVP50TA, MVP50TJ85, MVP50TL39

This product is currently out of stock and unavailable.

compare

Overview

Replaces 15 engine gauges and 50 functions. Remarkable full-color, enhanced TFT Glass Display (excellent viewability, even in direct sunlight) Pilot- Programmable Colors, Range Markings, Limits and Voice Alarms (for each parameter monitored) “System Page” to display Trims, Flaps, Wheel Status Lights, and many other system parameters and annunciators. 27 Pilot-Customized Annunciators at the top of the “Main Page”. Fuel Management, Timers, Clocks, Date, Weight & Balance.

Data Recording (.33 – 6 min, 665 hours @ 6 seconds). Pilot-Customized Checklists and Flight Plans. General Info, Flight Log, Start Log, Max & Min Data. Pilot easily can generate Custom Screens and download them to the MVP-50P through the USB port. Help Screen, GPS Interface and Data, Fuel Efficiency, Fuel Used for the Trip, Fuel Used Since Fill Up, Time to Empty, Distance to Empty, Fuel to Way Point, Time to Way Point, Distance to Way Point, Fuel Reserve, Time Reserve, Distance Reserve, Up Timer, Down Timer, Flight Timer, Engine Hours, Cycles, Date, Local and Zulu Time. Other functions, such as Fuel Level, Gyro Vac, Hydraulic Pressure, etc., may be added by purchasing an appropriate probe & harness, or transducer, etc. Using your current Resistive Fuel probes require our FFLM-4-XX to interface with the MVP-50T System. Torque, Oil Pressure & Temperature, Fuel Flow & Pressure, OAT, Amps, Volts, Multiple Fuel Screens, Pre-wired Harness, N1 and N2 hookups.

Includes EDC (Engine Data Converter), cables and harnesses, transducers, shunt (for amps), USB Download/ Upload Memory Stick, and our AV-17CP (Voice Warning Control Panel). Only 5.55”x 5.15”x 2.4” deep.

Part: MVP-50T-PT6, MVP-50T-W, MVP-50T-G, MVP-50T-L, MVP-50T-A, MVP-50T-J85, MVP-50T-L39 Categories: , , , Tag:
Select Package:

Pratt & Whitney PT-6 Turbo, Walters Engine Turbo, Garrett Turboprop, Lycoming Turboprop, Allison Turboprop, General Electric J85 Jet Engine, L39 Aircraft

Brands

Specifications

Model
Description
Part No.
MVP-50T-PT6
Pratt & Whitney PT-6 Turboprop Package
10-03160
MVP-50T-W
Walters Engine Turboprop Package
10-03161
MVP-50T-G
Garrett Turboprop Package
10-03162
MVP-50T-L
Lycoming Turboprop Package
10-03163
MVP-50T-A
Allison Turboprop Package
10-03164
MVP-50T-J85
General Electric J85 Jet Engine Package
10-03165
MVP-50T-L39
L39 Aircraft Package
10-03166

Accessory Info

 

Accessories for MVP Packages
Model
Description
Part No.
USB-64
USB Memory Stick, 64MB or larger, Used to upload and download data to the MVP
10-03186
CP-1-MVP
LED Intensity Control Pot. External pot used to control the display intensity.
10-03211
EDC-33T
Turbroprop/ Jet Engine Data Converter. Adding a second EDC to the MVP allows. Additional pressures, annunciators and other
functions to be monitored on the MVP (uses the Input Port 3 on the MVP).
10-03185
MVP-50T
Display Unit ONLY – May Be used to display parameters in a second location.
10-03202
Temperature Probes & Modules
Model
Description
Part No.

P-100-MVP

CHT Probe Screw-in Type (3/8″-24), Standard with most EI CHT instruments. Can be used in a pressure environment, 700°F Max.

10-03212
P-101MVP

CHT Probe Military Bayonet Type, 1/4 Turn Locking for quick removal. To be used with the A-101 Adaptor, 700°F Max.

10-03213
A-101MVP
CHT Adaptor for P-101 Probe, 3/8”-24
10-03216
P-102-18-MVP

CHT PROBE, 18 mm. Gasket Type 700°F Max.

10-03214
P-102-14-MVP

CHT PROBE, 14 mm. Gasket Type 700°F Max.

10-03217
P-102-12-MVP

CHT PROBE, 12 mm. Gasket Type 700°F Max.

10-03218
P-102-3/8-MVP

CHT PROBE, 3/8″ Piggy-Back Gasket Type 700°F Max.

10-03219
P-110-MVP

EGT/TIT PROBE, Hose Clamp Type. Used with 13/64″ Hole. Std w/ most kits. Wt: 1.6 oz.

10-03220
P-110-F-MVP

Fast Response EGT/TIT Probe, Hose Clamp Type. Requires a .130″ hole. Optional with most EGT pkgs. Weight: 1.3 oz.

10-03221
P-111-MVP

EGT/TIT PROBE 1/8″ NPT,< with Adjustable Depth. (Also approved for Oil Temp)

10-03222
P-111-F-MVP
Fast Response TIT probe, 1/8” NPT, .187” D
10-03223
P-112-MVP


EGT/TIT Probe, 7/16″ – 20, with Adjustable Depth. (AlsO approved for Oil Temp)

10-03224
P-114-MVP

EGT/TIT Probe, 1/4″ NPT, with Adjustable Depth. (Also approved for Oil Temp)

10-03225
P-114-F-MVP

Fast Response EGT/TIT Probe, 1/4″ NPT, with Adjustable Depth. (Also approved for Oil Temp)

10-03226
P-120-MVP

Oil Temp Probe Can be used in a pressure environment, 700°F Max.

10-03227
P-128-MVP

OAT/CARB Temp Probe. FAST Response/Exposed Tip, Uses a Precision connector, 700°F Max.

10-03228
P-104-MVP

Universal Probe Used to measure surface temperatures, 700°F Max.

10-03229
XDS-6′
One 6 ft TC harness w/ crimped D-Sub pins. Use to interface any temperature Probe to the MVP system. Specify length at time of order.
10-03192
Pressure Transducers & Modules
(Each include a Ccl-4D-6′ Harness when ordered with the MVP-50 or MVP-50T
Model
Description
Part No.
PT-30GA-MVP

Pressure Transducer, 1/8” NPT Male 0 to 40 PSI, Max. Over Pressure 90 PSI, Burst Pressure 120 PSI, Shock 100g, Material 316L stainless steel, 8 oz.

10-03232
PT-100GA-MVP

Presssure Transducer, 1/8” Male, 0 to 120 PSI, Max. Over Pressure 300 PSI, Burst Pressure 400 PSI, Shock 100g, Material 316L stainless steel, 8 oz.

10-03233
PT-300GA-MVP

Pressure Transducer, 1/8” NPT Male,> 0 to 300 PSI, Max. Over Pressure 900 PSI, Burse Pressure 1200 PSI, Shock 100g, Material 316L stainless steel, 8oz.

10-03235
PT-3000S-MVP

Pressure Transducer for Hydraulics, 1/8″ NPT Male, 0 to 3000 PSI, Max. Over Pressure 9000 PSI, Burst Pressure 10000 PSI, Shock 100g, Material 316L stainless steel, 8 oz.

10-03236
PT-30ABS-MVP
Absolute Pressure Transducer, 0 to 36 In Hg (Manifold Press or Cabin Altitude)
10-03238
PT-30ALT-MVP
Altitude Transducer
10-03239
PT-60ABS-MVP
Absolute Pressure Transducer, 0 to 70 In Hg (Manifold Pressure)
10-03240
PT-05DIFF-MVP
Differential Pressure Transducer, 0 to 60 In Hg (Vac Pressure or Cabin Diff Pressure)
10-03241
PT-04H20-MVP

Differential Pressure Transducer, 0 to 5 In H20

10-03242
FM-PR-MVP

Allows an EDC temperature channel to measure a pressure (operates w/ any EI MVP Pressure Transducer). Pressure transducer sold separately.

10-03204
DPIM-1-30-MVP
Differential Pressure Interface Module for aircraft that require fuel pressure to be Measured in reference to the upper deck. Includes a PT-30GA pressure transducer to measure the upper deck pressure.
10-03205
CBL-4D-6′
One 6’ 4-wire cable with crimped D-Sub pins. Used to interface any pressure transducer, fuel flow transducer or fuel level probe to the MVP system.
10-03183
Fuel Flow Transducers & Modules
Model
Description
Part No.
FT-60

Fuel Flow Transducer (Red Cube), .6 to 70+ GPH

10-01196
FT-90
Fuel Flow Transducer (Gold Cube), 3 to 125+ GPH
10-01224
FT-180
Fuel Flow Transducer (Black Cube), 5 to 250+ GPH
10-01197
FFDM-1-MVP-FT60

Fuel Flow Differential Module for aircraft w/ a pressure carburetor. Includes FT-60 or FT-90 transducer to measure the returned fuel. Please Choose the FT-60 or FT-90 at time of your order.

10-03244
FFDM-1-MVP-FT90
10-03245
FM-FLOW-P
Measures Fuel Flow from a pulsed injector signal.
10-03206
Fuel Level Probes
Model
Description
Part No.
RFLM-4-12
Resistive Fuel Level Module. Must be used w/ EI’s “EDC” to measure
up to 4 Resistive Fuel Level Sensors.
10-02772
RFLM-4–24
10-03231
P-300C
10-03194
3/4” Capacitive Fuel Level Probe w/ Accessories. (see our Accessories Page for details.) Specify Probe length at time of order.
10-00382
P-300C-Mini-1/8”

3/16” Capacitive Fuel Level Probe (see the Accessories Page for details)

10-03193
P-300C-Mini- 1/4”
10-03194
Volts & Amps Modules & Shunts
FM-VA-MVP-50
Volts/Amps Module. Allows any temperature or pressure channel on EI’s EDC to measure Voltage and Current on a separate bus. Comes w/ an S-50 or S-300 shunt.
10-03247
FM-VA-MVP-300
10-03248
MVP SCREEN ANNUNCIATOR INTERFACE UNITS
Model
Description
Part No.
VI-221
Voltage Interface Unit. Allows any temperature or fuel level channel on our EDC to measure the output voltage of any device. This voltage measurement can then be used to drive an annunciator (Canopy Latch, Gear Lights, Baggage Door, etc.) that will be
displayed on the MVP screen.
10-03187

Documents

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MVP-50T NON CERTIFIED TURBOPROP & JET ENGINE MONITOR”

There are no reviews yet.

Need Help?